upload
Valtorc International, Inc.
Domeniu: Industrial valves
Number of terms: 3113
Number of blossaries: 0
Company Profile:
Η ροή του υγρού στην αντίθετη κατεύθυνση από εκείνη που συνήθως εκτιμάται ως τυπική κατεύθυνση. Ορισμένες περιστροφικές βαλβίδες θεωρούνται αμφίδρομης κατεύθυνσης, αν και οι δυνατότητες πτώσης πίεσης λειτουργίας μπορεί να είναι χαμηλότερες και οι ρυθμοί διαρροής υψηλότεροι στην αντίστροφη ροή.
Industry:Industrial valves
A type of valve having a small orifice and a threaded, needle-like plunger. It allows precise regulation of flow, although it is generally used for, and is capable of, only relatively small flow rates.
Industry:Industrial valves
A type of valve used to control or limit the pressure in a system or vessel which can build up by a process upset, instrument or equipment failure, or fire.
Industry:Industrial valves
Een element of apparaat die informatie in de vorm van een hoeveelheid en zet ontvangt het aan informatie in de vorm van de dezelfde of een andere hoeveelheid. (Zie onder I / P)
Industry:Industrial valves
Il rapporto fra capacità di valvola e la valvola corsa. Solitamente è espressa graficamente sotto forma di una curva. Valvole di controllo hanno due tipi di caratteristiche intrinseche e installati. La caratteristica intrinseca è derivata da test la valvola con acqua come fluido e un calo di pressione costante attraverso la valvola. Quando le valvole sono installate in un sistema con pompe, tubi e raccordi, il caduto attraverso la valvola di pressione variano con il viaggio. Quando il flusso reale in un sistema è tracciato contro l'apertura della valvola, la curva è nota come la caratteristica di flusso installati. Valvole possono essere caratterizzate da plasmare le spine, gli orifizi o gabbie per produrre una curva particolare. Valvole sono caratterizzate al fine di cercare di modificare il guadagno della valvola. Guadagno della valvola è la variazione di flusso divisa per la variazione del segnale di controllo. Questo viene fatto nel tentativo di compensare la non linearità nel ciclo di controllo.
Industry:Industrial valves
The total force produced on the valve plug in any stated open position by the fluid pressure acting upon it. The particular style of valve, i. E. Single-ported, double-ported, flow-to-open, flow-to-close, has an effect on the amount of dynamic unbalance.
Industry:Industrial valves
Un aumento della pressione dell'aria all'attuatore è necessaria per causare la valvola aprire. Questo è un altro modo di dire che la valvola è fallire chiuso o normalmente chiuso.
Industry:Industrial valves
This condition exists when at a fixed upstream pressure the flow cannot be further increased by lowering the downstream pressure. This condition can occur in gas, steam, or liquid services. Fluids flow through a valve because of a difference in pressure between the inlet (Pl) and outlet (P2) of the valve. This pressure difference (Delta-P) or pressure drop isessential to moving the fluid. Flow is proportional to the square root of the pressure drop. Which means that the higher the pressure drop is the more fluid can be moved through the valve. If the inlet pressure to a valve remains constant, then the differential pressure can only be increased by lowering the outlet pressure. For gases and steam, which are compressible fluids, the maximum velocity of the fluid through the valve is limited by the velocity of the propagation of a pressure wave which travels at the speed of sound in the fluid. If the pressure drop is sufficiently high, the velocity in the flow stream at the vena contracta will reach the velocity of sound. Further decrease in the outlet pressure will not be felt upstream because the pressure wave can only travel at sonic velocity and the signal will never translate upstream. Choked Flow can also occur in liquids but only if the fluid is in a flashing or cavitating condition. The vapor bubbles block or choke the flow and prevent the valve from passing more flow by lowering the outlet pressure to increase the pres-sure drop. A good Rule Of Thumb on Gases and Steam service is that if the pressure drop across the valve equals or exceeds one half the absolute inlet pressure, then there is a good chance for a choked flow condition. ''Example'' P1 100 psig <br>P2 25 psig <br>_________ <br>Delta P = 75 P1 (ABS) = 100 + 14.7 or 114.7 1/2 of 114.7 = 57.35 Actual pressure drop = 75 Choked Flow is probable. The style of valve (that is whether it is a high recovery or a low recovery style) will also have an effect on the point at which a choked flow condition will occur.
Industry:Industrial valves
È la distanza tra la faccia dell'insenatura di apertura e il volto della presa di apertura di una valvola o di montaggio. Queste dimensioni sono disciplinate da specifiche ANSI/ISA. Si applicano le seguenti uniformi faccia a faccia dimensioni. ' ' SPECIFICA VALVOLA TIPO ' ': ' ' ANSI/ISA S75.03 INTEGRANTE GLOBO FLANGIATO STILE VALVOLE DI CONTROLLO ' ': ' ' ANSI/ISA S75.04 WAFER CONTROLLO VALVOLE VALVOLE DI CONTROLLO ANSUISA S75.20 FLANGIA SEPARABILI GLOBO STILE ' '
Industry:Industrial valves
I valori di alti e bassi pressione applicata al diaframma per produrre nominale viaggiano con condizioni indicate nel corpo della valvola. Le "condizioni di dichiarato" riferito a dire qui che la pressione effettiva scende a condizioni di funzionamento. Esempio: Una valvola di controllo può avere un set di pressione o panca diaframma inerente di 8 a 15 psig. Ma quando sottoposti ad un 600 psig. Pressione in ingresso, può iniziare ad aprire a 3 psig. Ed essere completamente aperto a 15 psig. È a causa delle forze che agiscono per il tappo della valvola e la direzione del flusso attraverso la valvola (flusso da aprire o flusso-a-chiusura) che la pressione del diaframma installato differirà dalla pressione diaframma inerente.
Industry:Industrial valves